The determining the photoluminescence intensity for assessing of the small bowel viability in the experiment
DOI:
https://doi.org/10.57125/FEM.2023.09.30.03Keywords:
Abdominal Surgery, Small Bowel, Viability, Laser Ray, Luminescence spectraAbstract
Aims: Explore the potential of utilising photoluminescence intensity (PhLI) indicators for evaluating bowel viability.
Methodology: PhLI of the small bowel walls on the initial, middle, and distal parts were measured in the control group (10 rats). The loop of the initial (10 rats), middle (10 rats) and distal (10 rats) part of the bowel with the mesentery was ligated. PhLI of the bowel walls were measured on the afferent (AP), efferent (EP) and ligated (LP) parts in 6 hours. LGN-503 argon laser with a wavelength of 458 nm and a power of 200 mW was used. Sections of bowels were taken for histological examinations.
Results: In AP revealed dystrophic disorders, in EP revealed minor changes, in LP revealed necrosis. The small bowel wall PhLI with altered viability decreased at the wavelength range λ = 470-490 nm, but the absolute indicators were significantly variable. The ratio of PhLI at wavelengths λ = 474 nm/λ = 489 nm on the initial, middle, distal bowel's parts didn’t significantly differ in control. The ratio on each bowel part didn’t significantly differ on the AP, EP, LP. The ratio's differences of the viable and non-viable bowels were significant on each part.
Conclusion: 1. The small bowel wall PhLI with altered viability decreases at the wavelength range λ = 470-490 nm. 2. The ratio of the small bowel walls PhLI indicators at the wavelengths λ=474/λ=489 nm is statistically significantly different in the bowel parts without altered viability and the bowel parts with necrosis. 3. Indicators of the ratio > 17 units testify the absence of viability altered, indicators in the range of 13-17 units testify the morphological disorders without necrosis, indicators < 13 units testify the bowel necrosis. 4. The determination of this ratio is promising for use in patients to assess its informativeness.
References
Calame P, Malakhia A, Turco C, Grillet F, Piton G, Delabrousse E. Transmural Bowel Necrosis from Acute Mesenteric Ischemia and Strangulated Small-Bowel Obstruction: Distinctive CT Features. AJR Am J Roentgenol. 2020;214(1):90-5. doi: 10.2214/AJR.19.21693
Johnson WR, Hawkins AT. Large Bowel Obstruction. Clin Colon Rectal Surg. 2021; Jul;34(4):233-241. DOI: 10.1055/s-0041-1729927
Detz DJ, Podrat JL, Muniz Castro JC, Lee YK, Zheng F, et al. Small bowel obstruction. Curr Probl Surg. 2021; Jul;58(7):100893. DOI: 10.1016/j.cpsurg.2020.100893.
Benedykt VV, Korobko LR, Chyzhyshyn BZ, Viitovych LY, Nikitina IM. Lethality analysis in patients with acute small bowel obstruction. adverse factors and possible ways to eliminate them. Wiad Lek. 2023;76(2):415-9. doi: 10.36740/WLek202302124
Besaha RM, Hrynchuk FV, Polyansky IYu. Diagnostic meaning of intestinal wall photoluminescence changes. Proc of SPIE. 2006; 6254:62541U-1. doi: 10.1117/12.679969
Patel Z, Thaha MA, Kyriacou PA. The effects of optical sensor-tissue separation in endocavitary photoplethysmography. Physiol Meas. 2018;39(7):075001. doi: 10.1088/1361-6579/aacc1d
Sugiura T, Okumura K, Matsumoto J, Sakaguchi M, Komori T, Ogi T, et al. Predicting intestinal viability by consecutive photoacoustic monitoring of oxygenation recovery after reperfusion in acute mesenteric ischemia in rats. Sci Rep. 2021;11(1):19474. doi: 10.1038/s41598-021-98904-x
Suzuki Y, Yamamoto M, Sugiyama K, Akai T, Suzuki K, Kawamura T, et al. Usefulness of a finger-mounted tissue oximeter with near-infrared spectroscopy for evaluating the intestinal oxygenation and viability in rats. Surg Today. 2021;51(6):931-40. doi: 10.1007/s00595-020-02171-8
Khosrawipour T, Li S, Steward E, Chaudhry H, Nguyen D, Khosrawipour V, et al. Assessment of Anastomotic Viability With Spectroscopic Real-time Oxygen Saturation Measurement in a Porcine Study. Surg Innov. 2022; 18:15533506221127378. doi: 10.1177/15533506221127378
Vaassen HGM, Sprakel J, Lips DJ. Fluorescence angiography to assess intestinal viability during emergency laparoscopy for small bowel obstruction-A video vignette. Colorectal Dis. 2022; 24(11):1444-5. doi: 10.1111/codi.16214
Ahmed T, Pai MV, Mallik E, Varghese GM, Ashish S, Acharya A, et al. Applications of indocyanine green in surgery: A single center case series. Ann Med Surg (Lond). 2022;10; 77:103602. doi: 10.1016/j.amsu.2022.103602
Joosten JJ, Longchamp G, Khan MF, Lameris W, van Berge Henegouwen MI, Bemelman WA, et al. The use of fluorescence angiography to assess bowel viability in the acute setting: an international, multi-centre case series. Surg Endosc. 2022; 36(10):7369-7375. doi: 10.1007/s00464-022-09136-7
Wildeboer A, Heeman W, van der Bilt A, Hoff C, Calon J, Boerma EC, et al. Laparoscopic Laser Speckle Contrast Imaging Can Visualize Anastomotic Perfusion: A Demonstration in a Porcine Model. Life (Basel). 2022;12(8):1251. doi: 10.3390/life12081251
Hou J, Strand-Amundsen R, Hodnebo S, Tonnessen TI, Hogetveit JO. Assessing Ischemic Injury in Human Intestine Ex Vivo with Electrical Impedance Spectroscopy. J Electr Bioimpedance. 2021; 12(1):82-88. doi: 10.2478/joeb-2021-0011
Verhoeff K, Mocanu V, Fang B, Dang J, Sun W, Switzer NJ, et al. Characterization of Near-Infrared Imaging and Indocyanine-Green Use Amongst General Surgeons: A Survey of 263 General Surgeons. Surg Innov. 2022;29(4):494-502. doi: 10.1177/15533506221094962
Heeman W, Wildeboer ACL, Al-Taher M, Calon JEM, Stassen LPS, Diana M, et al. Experimental evaluation of laparoscopic laser speckle contrast imaging to visualize perfusion deficits during intestinal surgery. Surg Endosc. 2023;37(2):950-7. doi: 10.1007/s00464-022-09536-9
Sherwinter D, Chandler P, Martz J. The use of tissue oxygen measurements compared to indocyanine green imaging for the assessment of intraoperative tissue viability of human bowel. Surg Endosc. 2022 Mar;36(3):2192-2196. doi: 10.1007/s00464-021-08737-y.
Cardiff RD, Miller CH, Munn Robert J. Manual hematoxylin and eosin staining of mouse tissue sections. CSH Protoc. 2014;2014(6):655-8. doi: 10.1101/pdb.prot073411.
Razali NM, Wah, Yap BW. Power comparisons of Shapiro-Wilk, Kolmogorov-Smirnov, Lilliefors and Anderson-Darling tests. JOSMA. 2011;2 (1):21-33. aviable from https://www.nrc.gov/docs/ML1714/ML17143A100.pdf